Friedrich CP06F10 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Acessórios de arrefecimento (hardware) Friedrich CP06F10. Friedrich CP06F10 User's Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1

Room Air ConditionerService and PartsManualCP06 - CP08 Svc Parts 2010 (05/10)CP06F10 CP08F100FPowerModeTimer0n/0 ffFanSpeedTempCoolMoneySaver®FanOnlyD

Página 2 - TABLE OF CONTENTS

10 Room Air ConditionerDisassemblyAir Handling Parts1.AIR GUIDE AND BLOWER1. Remove the front grille.2. Remove the cabinet.3. Remove the control box.4

Página 3 - Safety Precautions

Service Manual 11Electrical Parts1. Remove the cabinet.2. Remove the evaporator.3. Remove the orifice.4. Remove the blower.5. Remove the fan.6. Remove

Página 4 - 4 Room Air Conditioner

3. CAPACITOR12 Room Air Conditioner1. Remove the control box.2. Remove the screw which fasten control panel fromcontrol box.3. Remove the screw which

Página 5 - Service Manual 5

13 Room Air ConditionerDisassembly— Replacement of the refrigeration cycle.1. When replacing the refrigeration cycle, be sure toDischarge the refriger

Página 6 - Dimensions

Service Manual 14DisassemblyEquipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pin-off tool capableof making a vapo

Página 7 - Operation

Schematic DiagramCircuit DiagramLOCATIONNO.12345678Q'TYPER SET11111111DESCRIPTIONPOWER CORD ASSEMBLYFAN MOTORCOMPRESSORDISPLAY P.W.B ASSEMBLYMAIN

Página 8 - 8 Room Air Conditioner

Electronic Control DeviceSchematic DiagramService Manual16

Página 9 - Disassembly

Troubleshooting Guide Troubleshooting GuidePiping SystemFigure 16 is a brief description of the important components and their function in what is cal

Página 10 - Air Handling Parts

Troubleshooting GuideTroubleshooting GuideIn general, possible trouble is classified in two kinds.The one is called Starting Failure which is caused f

Página 11 - Electrical Parts

Troubleshooting GuideFails to StartImproper thermistorsettingLoose terminalconnectionImproper wiringCheck of power source.Drop of power voltage.Capaci

Página 12 - Refrigerating Cycle

Air Conditioner Service ManualTABLE OF CONTENTSSafety Precautions...

Página 13 - 3. CAPILLARY TUBE

Troubleshooting GuideELECTRIC PARTS TROUBLESHOOTING GUIDE:Possible Trouble 1• The unit does not operate.Is the Trans input powerAC 115V?Is the Trans o

Página 14 - Figure 15B-Charging

Troubleshooting GuideIs Temp.setting set lower than Room Temp.-0.5°C?Is the voltage No.10of IC01M 0V?• Exchange IC01M.• Set the Temp. setting to lower

Página 15 - Circuit Diagram

Troubleshooting GuideIs the voltage of Batteryabout over 2.3V?•Exchange Receiver Ass'y.Is the connection of CN-DISP1 all right?Is the voltage No.

Página 16 - Electronic Control Device

Troubleshooting GuideROOM AIR CONDITIONER VOLTAGE LIMITSNAME PLATE RATING MINIMUM MAXIMUM115V ± 10% 103.5V 126.5VYDEMERESUACTNIALPMOCFan motor will no

Página 17 - Troubleshooting Guide

Troubleshooting GuideYDEMERESUACTNIALPMOC,gnissimyllaitrapro,ecnalabfotuo,dekcarcfInaF.esionrotomnaFreplace it.,gnissimyllaitrapro,ecnalabfotuo,dekcar

Página 18

COMPLAINT CAUSE REMEDYCompressor cycles on Voltage Check the voltage. See the limits on theoverload. preceding page. If voltage is not within these li

Página 19 - 19 Room Air Conditioner

Exploded ViewExploded View249950268711-1264110238310237200268711-2135500146812W0CZZ359011731273267110135303749740352380152302148000130910346811349600W

Página 20 - • The unit does not operate

LocNo DESCRIPTION CP06F10130410 Base Assembly,Single 67302912130910 Cabinet Assembly,Single 67303714135303 Grille,Inlet 67306114135312 Grille Assembly

Página 21 - • Fan does not operate

Replacement Parts listLocNo DESCRIPTION CP08F10130410 Base Assembly,Single 67302917130910 Cabinet Assembly,Single 67303714135303 Grille,Inlet 67306114

Página 22 - Possible Trouble 6

Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540• (210) 357-4400 • FAX (210) 357-4490FRIEDRICH AIR CONDITIONING CO.Vis

Página 23 - 23 Room Air Conditioner

Service Manual 3Safety PrecautionsSafety PrecautionsTo prevent injury to the user or other people and property damage, the following instructionsmust

Página 24

4 Room Air ConditionerSafety PrecautionsPlug in the power plugproperly.• Otherwise, it will causeelectric shock or fire.Do not operate or stop theunit

Página 25 - 25 Room Air Conditioner

Service Manual 5Safety PrecautionsCAUTION•••••If water enters the product, turn off the thepower switch of the main body of appliance.Contact service

Página 26 - Exploded View

6 Room Air ConditionerDimensionsDimensionsOutside DimensionsThis symbol alerts you to the risk of electric shock. This symbol alerts you to hazards th

Página 27 - 27 Room Air Conditioner

1Ø, 115, 60Hz**)BW(76*)BD(80)。(ROODNIF。F)(ROODTUO345g(12.2 oz)Ø7.0, 2ROW 14STACKSØ5.0, 2ROW 16STACKSTURBO FANPROPELLER TYPE FAN WITH SLINGER RING3/36

Página 28

AirPurifierPowerTempModeTimerASwingFan Speed12435AutoSwing60FPowerModeTimer0n/0ffFanSpeedTempCoolMoneySaver®FanOnlyDryhrAutoSwing13246576. AUTO SWINGT

Página 29

DisassemblyDisassemblyMechanical Parts— Before the following disassembly, POWER SWITCH set to OFF and disconnect the power cord.1. FRONT GRILLE1. Open

Comentários a estes Manuais

Sem comentários