Only for training and service purposes
7.1 Low Ambient control
• This Function is for cooling operating in outdoor low temperature .
• If outdoor temperature drops below certain temperature, liquid back is prevented by reducing outdoor fan speed.
• It can prevent frosting of evaporator and keep cooling operation
7. Special Function
T2°C
T1°C
Outdoor pipe
Outdoor
Fan Speed
Setting Speed Off Off
Setting
Speed
Setting
Speed
7.2 Space control
Vanes angle can be controlled by pair, considering its
installation environment.
• For example direct drafts can be annoying, leading to
discomfort and reduced productivity vane control
helps to eliminate this problem.
• Easily controlled by wired remote control.
• Air Flow can be controlled easily regarding any space
environment.