USED WITH: LENGTH-FT. LIQUID SUCTION KIT#
All 9000 and 12000 BTU/h
Indoor Units
15 1/4” 3/8” T32150
35 1/4” 3/8” T32350
All 18000 BTU/h Indoor Units
15 1/4” 1/2” T42150
35 1/4” 1/2” T42350
All MW24Y3F and MW24C3F Units
15 1/4” 5/8” T52150
35 1/4” 5/8” T52350
All 30000 BTU/h Indoor Units and S24YF,
S36YF and C24YF Units
15 3/8” 5/8” T53150
35 3/8” 5/8” T53350
floor/ceiling universal ceiling suspended ceiling cassette
PERFORMANCE RATINGS
SYSTEM MODEL NO. S24YF S36YF C24YF
INDOOR MODEL MS24Y3F MS36Y3F MC24Y3F
OUTDOOR MODEL MR24UY3F MR36Y3F MR24UY3F
Capacity Cooling BTU/h 22200 34100 22200
Capacity Cooling Min - Max BTU/h 5000-27300 8500-36000 5000-27300
Sensible Heat Ratio 0.62 0.67 0.64
Capacity Heating
@
47°F BTU/h 24200 36400 24200
Capacity Heating Min - Max BTU/h 5000-29000 9200-42700 5000-29000
Capacity Heating
@
17°F BTU/h 15000 23400 14600
HSPF 8.5 8.5 8.5
SEER 15.0 14.0 15.0
EER 9.8 8.1 10.6
Moisture Removal Pts/h 7.4 7.4 6.4
Airflow (Low, Med, High) CFM 371/436/518 842/977/1089 436/536/618
Sound Rating - Indoor dB-A 38/43/47 41/45/48 38/43/45
Sound Rating - Outdoor dB-A 53 54 53
Operating Range COOL (HEAT) °F 0 to 115
(14-75)
0 to 115
(14-75)
0 to 115
(14-75)
ELECTRICAL DATA
Power Source 230/208-60-1 230/208-60-1 230/208-60-1
Min. Ampacity A 15.5 23 15.5
Cooling Watts W 2250 4220 2100
Max. TD Fuse/Breaker A 20 30 20
REFRIGERATION SYSTEM
Refrigerant R410A R410A R410A
Compressor Type Inverter (Twin Rotary) Inverter (Twin Rotary) Inverter (Twin Rotary)
Connections Flare Flare Flare
Liquid Line O.D. in 3/8 3/8 3/8
Suction Line O.D. in 5/8 5/8 5/8
Factory Precharge ft 50 50 50
Max. Line Length ft 165 165 165
Max. Height Difference ft 66 98 66
DIMENSIONS & WEIGHT
INDOOR UNIT
W x H x D in 39 x 7 7/8 x 25 3/4 65 3/8 x 9 1/2 x 27 1/2 32 5/8 x 9 5/8 x 32 5/8
Net Weight lbs 62 106 75
Shipping Weight lbs 82 134 97
OUTDOOR
UNIT
W x H x D
in 35
3
/8 x 32
5
/8 x 13 35
3
/8 x 32
5
/8 x 13 35
3
/8 x 32
5
/8 x 13
Net Weight
lbs 141 141 141
Shipping Weight
lbs 154 154 154
Friedrich Air Conditioning Co. | P.O. Box 1540 | San Antonio, TX 78295-1540 | (800) 541-6645 | fax (210) 357-4480 | www.friedrich.com
DSS-09 Printed in USA
Insulated line sets are available for all Friedrich split systems in 15 ft. and 35 ft. lengths. Each line set is equipped with flare nuts on both ends. Both liquid and
suction lines are insulated. Line sets can be joined together with field supplied double female connectors. Each system requires one line set for each indoor
unit installed. On multi-zone systems, line sets should be ordered based on individual indoor unit capacities not total system capacity. For example, a M18DYF
uses 2 line sets for 9,000 btu units, not 1 for the 18,000 btu product.
DRAIN PUMP USED WITH
DP-36 S36YF
NOTE: All models have low ambient capabilities built-in. Capacity is reduced as 0 degrees Fahrenheit is approached.
NOTE: All R410A models have 1/2˝ UNF 20 thread per inch charging and vacuuming ports. An adapter must be used
for 1/4˝ gauges. Adapter part number 67270018 is available through Friedrich parts distributors.
inverter model
Ceiling and Floor/ceiling universal heat pumps
Refrigeration line sets
All models use
environmentally
friendly R-410A
refrigerant.
R-410A
Comentários a estes Manuais